EPSILON

High-accuracy fuel level sensor

EPSILON EN

Fuel economy up to 30%

EPSILON ES

Save your money!

EPSILON

Save your money!

EPSILON ULB

Simple installation

EPSILON EZ

Explosion-proof protection

High-accuracy

The sensors of Epsilon series provide the measurement of fuel level in a vehicle tank with reduced error no more than 1-2%. This accuracy allows registering the minimal fuel charge and drain volume about 5-10 litres for trucks and 10-20 litres for heavy machinery. Compared with the standard resistive type fuel sensors the capacitive sensors are completely electronically operated and bear no moving parts, ensuring low inaccuracy, stability and reliability in operation.

Simple Installation

All sensors of Epsilon series have a modular design, e.g. the measuring head is mounted and dismantled independently of the fuel probe, which allows easy and quick change, if necessary, the measuring head without recalibration of the tank. This design allows simple installation even in not easily accessible places. 

Operation Safety

All Epsilon sensors are installed partly inside the fuel tank  and partly in close proximity to the fuel tank, e.g.  in hazardous explosive environment. So all Epsilon sensors have approved intrinsic safety barriers (of 1Ex protection type for Epsilon ES and EN, and 0Ex for Epsilon EZ). The explosion-proof protection of Epsilon sensors is confirmed by appropriate national and EU certificates.

 

Customer Support

Our support service operates for technical assistance of the customers all over the world. Experienced professionals will assist and advise in installation, configuration and operation of fuel level sensors Epsilon.

Our training programm is geared toward helping users to develop the necessary skill set and acquire knowledge and first-hand experience in installing and maintaining of our products.

 

SIGMA ULB

for liquids (LPG, water, chemicals) in barrels

The sensor is used for continuous non-invasive, digital, automatic measurement of LPG level and other liquids such as water, chemicals.

Sigma ULB measures the level mainly in aboveground stationary cylindrical metal tanks from 10 cm up to 4 meters depending of the liquid density.

The sensor has measurement error from 5% up to 1 mm depending on the model. Can be installed in the 0 explosive zone.

The sensor is a device that consists of one or two ultrasonic emitters / meters connected to a signal converter.

The converter is connected to intrinsically safe unit. The barrier is not included in the installation set and supplied as a separate, independent product.

Sigma ULB has RS 232, RS 485 output and can be easily connected to GPS tracker, PC, notebook, smartphone or digital indicator

 

Read more ...

EPSILON ESx-H

Sensor is purposed for fuel level measurement in containers and fuel tanks of vehicles. Sensor can be used with equipment that supports unified communication protocol Epsilon Data Exchange. Sensor has the electronic galvanic isolation through interface and power-supply circuits. Fuel level measurement is provided by a measuring head together with the probe submerged in fuel, which acts as a condenser, which capacity linearly depends on a fuel level in a tank.

EPSILON® ESx-H digital RS-232, RS-485 capacitive fuel level sensor is designed to measure fuel level in vehicle tanks and reservoirs with high precision (99% accuracy).

Main advantages:

  • High-resolution of the sensor, linearity, temperature stability;
  • Calibration table inside the sensor head. Allows transferring data directly in liters;
  • Galvanic isolation. Protects sensor head from power surges;
  • Monolith construction;
  • Wide range of possible probe length from 15 to 300 cm;
  • Ease of installation. Any hack saw can be used to cut the probe.

 

 

Sensor description

Sensor is purposed for fuel level measurement in fuel tanks of vehicles and stationary fuel tanks. Sensor can be used to measure level of other nonconductive liquids.
ES2-H, ES4-H sensor can be used with equipment that supports unified communication protocol Epsilon Data Exchange (hereinafter - EDE).
ESA-H model sensors can be used with analogue interface devices.
Sensor has electronic galvanic isolation through interface and power circuits.

Additional features

Model ES2-H sensors provide frequency interface (signal outputting from 500 to 1500 Hz frequency with linear frequency dependence vary with measured level of fuel). Also, model ES2-H sensors can provide analogue interface (signal outputting from 0 to 10 V voltage with linear voltage dependence vary with measured level of fuel), when using FV-10 frequency-to-voltage converter. 

Operation principle

A measuring head together with a sensor probe submerged in fuel provides fuel level measurement.
Sensor probe acts as a condenser, which capacity linearly depends on a fuel level in a tank.
Measuring head of the sensor performs linear conversion of sensor probe volume into fuel level digital code, processes acquired digital information with averaged results, measures sensor head temperature and outputs data in unified EDE protocol through RS-232 or RS-485 interfaces (for ES2-H and ES4-H models) or through analogue output (for ESA-H model). Fuel level data outputs in 16-bits (additionally, data output can be selected in 10-, 12-, 14- or 16-bits), temperature data outputs in 8-bits.
To measure the volume of monitored fuel calibration of fuel tank must be performed. This procedure determines volume-level code dependence of fuel.
Calibration procedure and installation of data exchange parameters (by using “EP30_Install” software) described in appendix A of “EH.000 IM. Installation Manual”.
Data exchange protocol EDE can be found in appendix B of aforementioned document.
The process of firmware updating and methods of saving and restoring configuration data described in appendix B of aforementioned document.

A measuring head together with the sensor probe provides fuel level measurement.

Measuring head

Measuring head contains:
- capacitymeter;
- digital circuit for data processing;
- data exchange device;
- power supply regulator and circuit for protection of incoming and outcoming electric circuits.
Sensor is connected to the external devices by the interface cable. Capacity meter performs conversion of current probe volume into digital code. Conversion is a linear function with variable parameters.
Digital circuit for data processing manages the capacity meter performance (limits of measurement, offset nulling, etc.), temperature compensation and received data scaling.
Data exchange device performs data exchange with GPS trackers, save/load of sensor calibration and configuration data and remote updating of embedded software. Sensor is mounted on the tank with self-drilling screws. Gasket ensures tightness between tank and flange.

Fuel probe

Fuel probe is a coaxial capacitor formed by an aluminum alloy tube (outer electrode) and an isolated aluminum rod (inner electrode). Required centering of the rod is achieved by placing a plug on the edge of the fuel probe and by isolated inner position-spacers.

 

Installation of the sensor

Evaluation of fuel probe length when ordering

To evaluate the proper fuel probe length it is necessary to measure fuel tank depth in place of intended sensor installation and to calculate length of fuel probe according to the formula:
Lm = L- Δ,
where Lm – approximate length of fuel probe as per order;
L– tank depth in place of intended sensor installation;
Δ - distance between measuring part and tank bottom.
Recommended values for distance Δ:
- Δ = 15…20 mm – for rigid metal tanks (the deeper the tank the bigger the distance);
- Δ = 30 mm – for tanks without enough rigidity (such as plastic tanks of considerable height).
During installation process, the necessity of reducing fuel probe length may arise (on-site).
You can find the procedure of reducing fuel probe length in “EH.000-EN IM_ Installation Manual”.

 

 

Technical characteristics

Parameter or characteristic name Unit Value Notes
Operational temperature range, °С °C – 40 … + 75  
Mode of operation   Continuous  
Ranges of permissible reduced error of level measurement % ± 1,0  
Code length of presentation of measurement results bit 10/12/14/16 Level
8 Temperature
Power supply voltage, operational range V +9,5 … +36 Nominal 
Current consumption mA 25  
Acceptable exposure of impulse voltage through power circuits   + 120, long-term
+ 180 V, 1 sec.
- 1000 V, long-term
 
Acceptable short-term exposure of potentials difference between signal ground and body of measuring head   ±1500 V, 1 sec.  
Digital interface    RS-485 ES4-H models
RS-232 ES2-H models
Exchange rate through the serial port, bps    2400, 4800, 9600, 19200, 38400, 57600, 115200 programmed
Frequency interface (when using ES.700 compatible device), Hz   500…1500 ES2-H models
Analogue interface. Upper an lower limits are setting by software in the range of,  V   0…10
(default)
 ESA-H models
Analogue interface (when using FV-10 Frequency-to-voltage converter), mV   0…10  
Height of a measuring head over a tank top, including flange and gasket mm 26  

Manuals

 

ESx-H_User-manual

 

For ES2-H/ES4-H

EP30 Install


For ESA-H analog
 

EP31 Install

 

ES Install Easy

ES Install Easy v.1.0.0.14

 

 

 

RCS on GITEX 2024

We are excited to announce that RCS will be participating in GITEX Global 2024, where we will showcase our latest innovations and products that have already received positive feedback from our partners. We warmly invite all attendees to visit us at our stand H26-11, Hall 26, at the Dubai World Trade Center from 14 to 20 October, 2024. Come meet the team and explore the full range of RCS solutions, along with the benefits they offer. We look forward to connecting with you!

 

RCS on Warsaw Gas Days 2018

Warsaw Gas Days 2018 is a continuation of the International GasShow Fair, one of the key events for the LPG / CNG / LNG industry. A large, stabilised market and geographical location has allowed us to invite visitors from all over the world, including from Italy, Turkey, Holland, Germany, the Czech Republic, Slovakia, Lithuania, Ukraine, Russia, Hungary, Slovenia, Croatia, Serbia, Albania, the USA, as well as countries in South America and Asia.

Contact details

Address

Novozabarskaya Str. 2/6

Kiev, Ukraine 04074

Email Address

This email address is being protected from spambots. You need JavaScript enabled to view it.

This email address is being protected from spambots. You need JavaScript enabled to view it.

This email address is being protected from spambots. You need JavaScript enabled to view it.

This email address is being protected from spambots. You need JavaScript enabled to view it.

Phone Number

+38 093 887 46 26

Quick Contact